load cell
New Products
Contact Sinoder
Tel: 0086-18037503060- Contact Person:Mr Rockwell
- E-mail: rockwell@sinoder.com
- Address: Room 1101, Building A, Ccmall Plaza, No.198 West Jianshe Road, Zhengzhou City, Henan Province, China
S type load cell
S type load cell F4607 25kg to 10000kg
S type load cell F4607 25kg to 10000kg·S shape load cell, high accuracy
·Could measure pull and push force
·Mainly used in Force Gauge, hopper scale, and industrial weighing system
technical parameters | |
Specifications | Technique |
Capacity | 25,50,100,200,250,500,750,1000,1500,2000,2500,5000,10000kg |
Rated output | 3.0±1%mV/V |
Zero balance | ± 0.06F.S. |
Non-linearity | 0.03%F.S. |
Hysteresis | 0.03%F.S. |
Repeatability | 0.03%F.S. |
Creep (30 Min) | 0.024%F.S. |
Temp.effect on output | 0.02%F.S./10℃ |
Temp.effect on zero | 0.02%F.S./10℃ |
Input impedance | 381±10Ω |
Output impedance | 350±5Ω |
Insulation | ≥5000MΩ/100VDC |
Recommended excitation | 5-15V |
Maximum excitation | 20V |
Compensated temp range | -10~40℃ |
Operation temp range | -30~70℃ |
Safe overload | 150%F.S. |
Ultimate overload | 200%F.S. |
Cable size | φ5*3m |